4 dds-20 gige (10/100/1000 ethernet) backup switch, 1 dds-20 – gige switch front panel connectors, 2 dds-20 – gige switch back panel connectors – Comtech EF Data RCS20 User Manual

Page 123: 2 j19 | bu data out, 3 j20 | modem fault monitor

background image

RCS20 M:N Redundancy Switch

Revision 15

Electrical Interfaces

MN-RCS20 and CD-RCS20

5–23

5.4 DDS-20 GigE (10/100/1000 Ethernet) Backup Switch

5.4.1 DDS-20 – GigE Switch Front Panel Connectors

Figure 5-13 DDS GigE Switch – Front Panel Connectors

5.4.1.1 J1 | CH1 DATA IN through J9 | CH 9 DATA IN

The J1 | CH1 DATA IN through J9 | CH9 DATA IN ports are RJ-45, 10/100/1000 Ethernet Data ports for
connecting channels 1 through 9.

5.4.2 DDS-20 – GigE Switch Back Panel Connectors

Figure 5-14 DDS GigE Switch – Back Panel Connectors

5.4.2.1 J10 | CH 9 DATA OUT through J18 | CH1 DATA OUT

The J10 | CH 9 DATA OUT through J18 | CH1 DATA OUT ports are RJ-45, 10/100/1000 Ethernet Data
ports for connecting to the prime modem 1 through 9 Ethernet data ports.

5.4.2.2 J19 | BU DATA OUT

The J19 | BU DATA OUT port is a RJ-45, 10/100/1000 Ethernet Data port for connecting to Backup 1
Ethernet Data port.

5.4.2.3 J20 | MODEM FAULT MONITOR

The J20 | MODEM FAULT MONITOR port is a 15-pin High-Density Female Type D Connector for
connecting prime modems 1 through 9 and backup modem 1 alarm ports for fault monitoring.

Pin Number

Signal Name

Direction

1

Prime Modem 1 Fault

---

2

Prime Modem 2 Fault

---

3

Prime Modem 3 Fault

---

4

Prime Modem 4 Fault

---