beautypg.com

4 test menu tree, 8 switch minor alarms 2 – Comtech EF Data RCS20 User Manual

Page 93

background image

RCS20 M:N Redundancy Switch

Revision 15

User Interfaces

MN-RCS20 and CD-RCS20

4–59

4.3.3.8 SWITCH MINOR ALARMS 2

These screens display minor alarms.

CAUTION
Masking alarms may cause undesirable modem performance

Key

Label

Function

S1

Press to move the blinking cursor up through the list of faults.

S2

Press to move the blinking cursor down through the list of faults.

S3

TOG MODE Used to toggle between YES (masked) and NO (not masked).

S4

NEXT

Press to cycle to the next screen.

Numeric Keypad ---

Press or to abort programming (no switch parameters changed).
Press to load the information on the screen into the switch parameter table.

4.3.4 TEST Menu Tree

4.3.4.1 SWITCH SYSTEM TESTS

This screen allows execution of the following tests:

SWITCH MINOR ALARMS

MASK

COMMUNICATIONS : PASS NO

PRIME MODEM STATUS : FAIL NO

BACKUP MODEM STATUS : PASS NO

PRIME MODEM CONFIGURATION : FAIL NO

TOG MODE NEXT

NEXT

SWITCH SYSTEM TESTS

SYSTEM COMMUNICATION TEST

MODEM PARAMETER COMPATIBILITY TEST

LAMP TEST

COMM PARM LAMP NEXT