25 rdm fallback configuration, 1 programming steps – Comtech EF Data RCS20 User Manual
Page 84

RCS20 M:N Redundancy Switch
Revision 15
User Interfaces
MN-RCS20 and CD-RCS20
4–50
4.3.2.25 RDM FALLBACK CONFIGURATION
This screen allows the user to configure the fallback programming for the optional Reference Distribution
Module (RDM). The RDM has two reference inputs (EXTA, EXTB) and an internal frequency source
(INT). The fallback programming allows automatic switching between these three frequency sources.
There are clock activity detectors on each frequency source, and automatic switching (fallback) will occur
if there is no activity for the current frequency source. The following fallback modes are available:
EXTA ONLY
INT ONLY
EXTA INT
INT EXTA
EXTA EXTB
EXTA EXTB INT
INT EXTA EXTB
For these modes, the system will switch to the leftmost source that has clock activity. For example, if the
fallback mode is EXTA EXTB INT, and there is no activity on EXTA or EXTB, then the INT source
will be selected. If activity returns to EXTB, then EXTB will be selected, and if activity returns to EXTA,
then EXTA will be selected.
4.3.2.25.1 Programming steps:
1.
Press
2.
Continue pressing
3.
Press
4.
Press
Key
Label
Function
S1
TOG MODE Cycle through the above listed fallback configurations.
S2
---
N/A
S3
---
N/A
S4
RETURN
Cycle back to the REFERENCE DISTRIBUTION CONFIGURATION Screen.
Numeric Keypad ---
Press
Press
RDM INTERNAL REFERENCE CONFIGURATION
FALLBACK : EXTA ONLY
TOG MODE RETURN