beautypg.com

A.3.20 opcode: <240eh> query time, A.3.21 opcode: <240fh> query date, A.3.22 opcode: <2410h> query time and date – Comtech EF Data RCS20 User Manual

Page 176

background image

RCS20 M:N Redundancy Switch

Revision 15

Remote Operations

MN-RCS20 and CD-RCS20

A–34

A.3.19

Opcode <2404h> Query RCS20 Switch Control Mode

Query Response Data Field (1 Byte)

<1>

Control Mode

0 = Front Panel, 1 = Terminal Mode, 2 = Remote Port

A.3.20

Opcode: <240Eh> Query Time

Query Response Data Field (3 Bytes)

<1>

Hour

0 - 23

<1>

Minute

0 - 59

<1>

Second

0 - 59

A.3.21

Opcode: <240Fh> Query Date

Query Response Data Field (3 Bytes)

<1>

Year

0 – 99

<1>

Month

0 - 11

<1>

Day

0 - 30

A.3.22

Opcode: <2410h> Query Time and Date

Query Response Data Field (6 Bytes)

<1>

Year

0 – 99

<1>

Month

0 - 11

<1>

Day

0 - 30

<1>

Hour

0 - 23

<1>

Minute

0 - 59

<1>

Second

0 - 59

A.3.23

Opcode <2600h> Set RCS20 Switch Control Mode

Command Data Field (1 byte):

<1>

Control Mode

0 = Front Panel, 1 = Terminal, 2 = Remote Port (Computer RLLP)