Controls, LEDs, and Connectors

CPCI-6200 Installation and Use (6806800J66E)

71

3.3.9

Serial Port Connector, J16

The serial port connector (COM1) is located on the front panel.

Note: G1 and G2 are connected to ground.

3.3.10 Board Insertion/Extraction Connector, P1

A board insertion and extraction connector is located near the front panel. This connector is
used to detect a board insertion or extraction event. The latch connector on the front panel is
connected to this connector.

Pins 1 and 2 indicate board insertion or extraction status. Pin 2 is used with the PCI Bridge while
pin 3 is used with the IPMI controller.

A closed latch indicates board insertion. In this case, pin 2 and 3 are shorted and
FP_EJECTSW = 1, BOARD_EJECT = 0.

Figure 3-3

Serial Port Connector Pinout, J16

6
7
8
9

1

6

5

9

1
2
3
4
5

Not Connected
RXD
TXD
Not Connected
GND

Not Connected
RTS#
CTS#
Not Connected

Table 3-10 Front Panel Latch Pinout, P1

Pin Number

Signal

1

GND

2

BOARD_EJECT

3

FP_EJECTSW

G1

NC

G2

NC