Environmental Requirements

The environmental conditions must be tested and proven in the used system configuration.
These conditions refer to the surroundings of the board within the user environment.

Operating temperatures refer to the temperature of the air circulating around the board
and not to the component temperature.

To ensure that the operating conditions are met, forced air cooling is required within the
shelf environment.

The environmental values given in the table below only apply to the board without any
accessories. If installing accessories, their environmental requirements must also be
taken into account.

Product Damage
High humidity and condensation on surfaces cause short circuits.
Do not operate the product outside the specified environmental limits. Make sure the
product is completely dry and there is no moisture on any surface before applying power.

Table 2-1 CPCI-6200 Environmental Requirements

Characteristics

Operating

Non-Operating

Operating Temperature

0°C to +55°C (32°F to 131°F)
entry air with forced-air cooling

–40°C to +70°C (104°F to 158°F)

Temperature Change

+/-0.5°C/min according to NEBS
Standard GR-63-CORE

Forced Air Flow

8.7 LFM at 55°C (131 °F)
ambient temperature

Relative Humidity

5% to 90% Non-Condensed

5% to 90%Non-Condensed

Vibration

1.0 G sine sweep, 5–200 Hz,
0.25 octaves/min, all 3 axis
(operating)

5–20 Hz at 0.01 g/Hz
20–200 Hz at -3.0 dB/octave
Random 5–20 Hz at 1 m/sec
Random 20–200 Hz at -3 dB/Octave