Environmental Requirements
The environmental conditions must be tested and proven in the used system configuration.
These conditions refer to the surroundings of the board within the user environment.
Operating temperatures refer to the temperature of the air circulating around the board
and not to the component temperature.
To ensure that the operating conditions are met, forced air cooling is required within the
shelf environment.
The environmental values given in the table below only apply to the board without any
accessories. If installing accessories, their environmental requirements must also be
taken into account.
Product Damage
High humidity and condensation on surfaces cause short circuits.
Do not operate the product outside the specified environmental limits. Make sure the
product is completely dry and there is no moisture on any surface before applying power.
Table 2-1 CPCI-6200 Environmental Requirements
Characteristics
Operating
Non-Operating
Operating Temperature
0°C to +55°C (32°F to 131°F)
entry air with forced-air cooling
–40°C to +70°C (104°F to 158°F)
Temperature Change
+/-0.5°C/min according to NEBS
Standard GR-63-CORE
Forced Air Flow
8.7 LFM at 55°C (131 °F)
ambient temperature
Relative Humidity
5% to 90% Non-Condensed
5% to 90%Non-Condensed
Vibration
1.0 G sine sweep, 5–200 Hz,
0.25 octaves/min, all 3 axis
(operating)
5–20 Hz at 0.01 g/Hz
20–200 Hz at -3.0 dB/octave
Random 5–20 Hz at 1 m/sec
Random 20–200 Hz at -3 dB/Octave