beautypg.com

Table 7-32, Signal status sensor, Control via ipmi – Artesyn CPCI-6200 Installation and Use (May 2015) User Manual

Page 176

background image

Control via IPMI

CPCI-6200 Installation and Use (6806800J66E)

176

Hysteresis Support

0x02

Readable and Setable

Threshold Access Support

0x02

Readable and Setable

Event Message Control

0x00

Per Threshold / Discrete State

Reading Definition

Analog reading byte

Analog sensor reading

Table 7-32 Signal Status Sensor

Feature

Raw Value

Description

Sensor Name

Signal Status

-

Sensor LUN

0x00

-

Sensor Number

0x85

-

Entity ID

0x07

-

Sensor Type

0xD2

Artesyn-specific Discrete Digital

Event/Reading Type

0x6F

Discrete (sensor-specific)

Assertion Event Mask(Byte 15)

0x08

-

Assertion Event Mask(Byte 16)

0x00

-

Deassertion Event Mask(Byte 17)

0x08

-

Deassertion Event Mask(Byte 18)

0x00

-

Threshold Mask(Byte 19)

0x0F

-

Threshold Mask(Byte 20)

0x00

-

Base Unit

0x00

(unspecified)

Rearm mode

0x01

Auto

Hysteresis Support

0x00

No Hysteresis or unspecified

Threshold Access Support

0x00

No Tresholds

Event Message Control

0x00

Per Threshold / Discrete State

Reading Definition

-

-

Table 7-31 SEL Fullness Sensor (continued)

Feature

Raw Value

Description