beautypg.com

6 jumper settings, Table 5-11, Wire interconnection list rj-45 to db-9 – Artesyn CPCI-6200 Installation and Use (May 2015) User Manual

Page 122: Transition module preparation and installation

background image

Transition Module Preparation and Installation

CPCI-6200 Installation and Use (6806800J66E)

122

Connecting an CPCI-6200 to a PC terminal requires that the adapter described above be
attached to a standard RJ-45-to-RJ-45 shielded cable with straight through signaling.

The pinout information for this adapter is in the following table:

5.6

Jumper Settings

This section describes the jumper settings that are required for proper operation prior to
installing the CPCI-6115-MCPTM transition module into a chassis backplane. Many boards are
already factory configured based on customer requirements, but the jumper settings should
be verified before installation.

Table 5-11 Wire Interconnection List RJ-45 to DB-9

RF-45 Signal

RJ-45 Pin

DB-9 Pin

DB-9 Signal

DCD

1

4

DTR

RTS

2

8

CTS

GND

3

5

GND

TxD

4

2

RxD

RxD

5

3

TxD

GND

6

OPEN

CTS

7

7

RTS

DTR

8

6

DSR

Damage of the Product
Setting/resetting the switches during operation can cause damage of the product.
Check and change switch settings before you install the product.