Dell TL2000 User Manual
Page 107

–
Sequential
:
In
sequential
mode,
the
library’s
firmware
predefines
the
selection
of
the
cartridges.
After
initialization,
the
firmware
causes
the
library
to
select
the
first
available
cartridge
found
(counting
from
the
I/O
Station
through
slot
23)
for
loading
into
the
drive.
-
Autoload
:
Sequential
mode
with
autoload
mode
ON
loads
the
first
available
cartridge
(slot
with
the
lowest
numerical
value
that
contains
a
cartridge)
automatically
if
the
library
powers
ON
with
an
empty
drive.
-
Loop
:
Sequential
mode
with
loop
mode
ON
loads
the
cartridge
in
the
lowest
numerical
slot
after
the
cartridge
in
the
highest
numerical
slot
has
been
filled
and
sent
back
to
its
home
slot.
This
allows
endless
backup
operations
without
user
interaction.
-
Starting
Sequential
Mode
v
Autoload
Option:
–
If
the
Autoload
option
is
set
to
ON
(Configure
→
Library
→
Autoload
),
the
accessor
will
load
the
first
cartridge
(cartridge
located
in
the
slot
with
the
lowest
numeric
value)
found
in
the
storage
inventory
area
into
the
drive
upon
power
ON
of
the
library.
If
the
library
powers
on
with
a
cartridge
already
in
the
drive,
sequential
mode
will
start
with
that
cartridge
unless
the
host
issues
a
rewind
and
unload
command
to
the
drive.
In
that
case,
the
next
cartridge
in
sequence
will
be
loaded
into
the
drive.
–
If
the
Autoload
Option
if
OFF
,
sequential
mode
must
be
started
by
selecting
the
Move
Cartridges
option
(Control
→
Move
Cartridges
)
to
load
the
first
cartridge
(or
any
cartridge)
into
the
drive.
Whatever
cartridge
is
loaded
into
the
drive,
that
is
where
the
sequence
starts
from.
For
example,
if
a
cartridge
from
the
fifth
lowest
numeric
storage
slot
containing
a
cartridge
is
loaded
using
the
Move
Cartridges
option,
after
the
host
issues
a
rewind/unload
command,
the
next
cartridge
loaded
will
be
the
cartridge
from
the
next
higher
numeric
slot.
Cartridges
need
not
be
in
contiguous
slots.
v
Loop
Option:
If
the
Loop
option
is
set
to
ON
(Configure
→
Library
→
→
Loop
),
when
the
last
cartridge
(cartridge
in
the
highest
numeric
slot)
is
unloaded
and
placed
back
into
storage,
the
accessor
will
immediately
start
over
again
loading
the
first
cartridge
into
the
drive.
-
Stopping
Sequential
Mode
:
To
stop
sequential
mode,
use
the
Move
Cartridges
option
from
the
Control
menu
(Control
→
Move
Cartridges
)
to
unload
the
drive.
the
next
sequential
cartridge
will
NOT
be
loaded.
To
restart
sequential
mode,
use
the
same
Control
menu
command
to
load
a
cartridge.
The
loading
sequence
will
resume
from
that
numeric
slot
in
the
cartridge
inventory.
v
Active
Slots
-
the
number
of
active
slots
you
want
to
assign
to
each
logical
library.
Note:
Slots
can
be
reserved
so
that
they
are
invisible
to
the
host.
It
may
be
necessary
to
set
the
number
of
Active
Slots
to
match
the
number
of
slots
that
are
available
to
the
ISV
software.
v
Auto
Clean
-
Use
this
menu
item
to
enable
the
Auto
Clean
function.
All
cleaning
cartridges
must
have
″CLNxxxLx″
as
part
of
the
bar
code.
The
cleaning
cartridge
can
be
stored
in
any
data
cartridge
slot.
Note:
The
universal
cleaning
cartridge
has
a
bar
code
CLNUxxLx.
This
cleaning
cartridge
is
used
to
clean
all
LTO
generation
tape
drives.
Chapter
5.
Operations