Altpll_reconfig ip core references, Altpll_reconfig parameters, Altpll_reconfig ip core references -1 – Altera MAX 10 Clocking and PLL User Manual
Page 77: Altpll_reconfig parameters -1

ALTPLL_RECONFIG IP Core References
7
2015.05.04
UG-M10CLKPLL
ALTPLL_RECONFIG Parameters
Table 7-1: ALTPLL_RECONFIG IP Core Parameters for MAX 10 Devices
This table lists the IP core parameters applicable to MAX 10 devices.
Page
Parameter
Value
Description
Parameter
Settings
Currently Selected
Device Family
—
Specifies the chosen device family.
Which scan chain type
will you be using?
—
The scan chain is a serial shift register chain
that is used to store settings. It acts like a
cache. When you assert the
reconfig
signal,
the PLL is reconfigured with the values in the
cache. The type of scan chain must follow the
type of PLL to be reconfigured. The scan
chain type has a default value of Top/
Bottom.
Do you want to specify
the initial value of the
scan chain?
No, leave it
blank,
Yes, use this file
for the content
data
Specifies the initial value of the scan chain.
Select No, leave it blank to not specify a file
or select Yes, use this file for the content
data to browse for a
.hex
or
.mif
file.
The option to initialize from a ROM is not
available. However, you can choose to add
ports to write to the scan chain from an
external ROM during runtime by turning on
Add ports to write to the scan chain from
external ROM during run time.
Add ports to write to
the scan chain from
external ROM during
run time
On, Off
Turn on this option to take advantage of
cycling multiple configuration files, which are
stored in external ROMs during user mode.
©
2015 Altera Corporation. All rights reserved. ALTERA, ARRIA, CYCLONE, ENPIRION, MAX, MEGACORE, NIOS, QUARTUS and STRATIX words and logos are
trademarks of Altera Corporation and registered in the U.S. Patent and Trademark Office and in other countries. All other words and logos identified as
trademarks or service marks are the property of their respective holders as described at
www.altera.com/common/legal.html
. Altera warrants performance
of its semiconductor products to current specifications in accordance with Altera's standard warranty, but reserves the right to make changes to any
products and services at any time without notice. Altera assumes no responsibility or liability arising out of the application or use of any information,
product, or service described herein except as expressly agreed to in writing by Altera. Altera customers are advised to obtain the latest version of device
specifications before relying on any published information and before placing orders for products or services.
www.altera.com
101 Innovation Drive, San Jose, CA 95134