beautypg.com

Altera MAX 10 Clocking and PLL User Manual

Page 66

background image

Port Name

Condition

Description

inclk[]

Required

Clock input of the clock buffer.
Input port

[1 DOWNTO 0]

wide.

You can specify up to two clock inputs,

inclk[1..0]

.

Clock pins, clock outputs from the PLL, and core signals can

drive the

inclk[]

port.

Multiple clock inputs are only supported for the global clock

networks.

Table 5-3: ALTCLKCTRL Output Ports for MAX 10 Devices

Port Name

Condition

Description

outclk

Required

Output of the clock buffer.

Related Information

Global Clock Control Block

on page 2-4

Global Clock Network Power Down

on page 2-6

Clock Enable Signals

on page 2-7

Guideline: Clock Enable Signals

on page 3-1

UG-M10CLKPLL

2015.05.04

ALTCLKCTRL Ports and Signals

5-3

ALTCLKCTRL IP Core References

Altera Corporation