beautypg.com

Bypassing pll counter – Altera MAX 10 Clocking and PLL User Manual

Page 52

background image

LFR[4]

LFR[3]

LFR[2]

LFR[1]

LFR[0]

Setting (Decimal)

1

0

1

0

0

20

1

1

0

0

0

24

1

1

0

1

1

27

1

1

1

0

0

28

1

1

1

1

0

30

Table 4-4: Loop Filter High Frequency Capacitor Control

LFC[1]

LFC[0]

Setting (Decimal)

0

0

0

0

1

1

1

1

3

Related Information

Programmable Bandwidth

on page 2-19

Programmable Bandwidth with Advanced Parameters

on page 4-10

Programmable Bandwidth Parameter Settings

on page 6-2

Bypassing PLL Counter

Bypassing a PLL counter results in a multiplification (

M

counter) or a division (

N

,

C0

to

C4

counters) factor

of one.

Table 4-5: PLL Counter Settings

Description

PLL Scan Chain Bits [0..8] Settings

LSB

MSB

PLL counter

bypassed

X

X

X

X

X

X

X

X

1

(9)

PLL counter not

bypassed

X

X

X

X

X

X

X

X

0

(9)

To bypass any of the PLL counters, set the bypass bit to 1. The values on the other bits are ignored.

(9)

Bypass bit

4-14

Bypassing PLL Counter

UG-M10CLKPLL

2015.05.04

Altera Corporation

MAX 10 Clocking and PLL Implementation Guides

Send Feedback