G-2 simulator – KEYENCE KV Series User Manual
Page 212

Appendices
2-188
Appendices
G-2
Simulator
■ Function list and menu
A brief description of functions and commands (menu buttons) used to execute the
functions are given below.
For detailed descriptions, refer to the corresponding reference page.
Reading/saving a window
Reading and saving a monitor all window
File
➔ Open Window
2-111
➔ Save Window As
Reads a monitor all file. Saves the current monitor all window with a
new file name (extension: kal).
Reading and saving a registration monitor window
File
➔ Open Window
2-121
➔ Save Window As
2-120
Reads a registration monitor file. Saves the current registration monitor
window with a new file name (extension: kre).
Setting the simulator operation status
Setting and deleting the break condition
Settings
➔ Set Break Condition
2-98
Edit
➔ Delete Break Condition
Setting the wait time
Settings
➔ Wait Time
2-130
Setting the scan time
Settings
➔ Scan Time
2-100
Setting the watch dog timer
Settings
➔ Set Watch Dog Timer
2-100
Executing and stopping the simulator
Executing scans
Execute
➔ Execute Continuous Scan
2-92
➔ Execute One Scan
2-93
Two execution modes are available: continuous scan and one scan.
Executing steps
Execute
➔ Execute Continuous Step
2-102
➔ Execute One Step
2-103
➔ Execute High-speed Step
2-104
➔ Execute Continuous Step in Reverse
➔ Execute One Step in Reverse
Five execution modes are available: continuous step, one step,
high-speed step, continuous step in reverse, and one step in reverse.
When steps are executed, the mnemonic window is displayed.
Stopping and pausing execution of step/scan
Execute
➔ Stop
2-108
➔ Pause
Reset
Execute
➔ Reset
2-108
Returns the current values to the default values according to the
specification given by "MEMSW".
Device all clear
Execute
➔ Device All Clear ➔ DM All Clear
2-108
➔ Latching Relay All Clear
➔ Counter All Clear
Sets the current value of each device to 0 (OFF).
Ladder monitor
Displaying a ladder monitor window
File
➔ Ladder Monitor
2-144
Displays the ladder diagram of the ladder program currently being
simulated.
In this window, the ON/OFF status of bit devices can be changed, and
the attribute (bit count and radix) can be changed using the dialog bar.
Registering devices to another monitor
2-114
For registration, select a device to be monitored, and then drag and
drop it to the registration monitor window or the monitor all window
while pressing and holding the left mouse button.
KVSKA Appendix.P65
08.3.11, 11:26 AM
188