Appendices
DM1485 X #65536 + DM1484
(output pulses)
DM1481
(operation)
Frequency (Hz)
DM1480
(startup)
0
DM1482
DM1482
Time (ms)
(acceleration time)
(deceleration time)
Setting contents
Setting range
DM1480
Ramp up-and-down control startup frequency (Hz)
200 to 50000
DM1481
Ramp up-and-down control operating frequency (Hz)
200 to 50000
(value larger than
startup frequency)
DM1482
Ramp up-and-down control acceleration/deceleration
0 to 4000
time (ms)
DM1484
Number of output pulses (lower 16 bits)
0 to 65535
(2 or more when
DM1485 is 0)
DM1485
Number of output pulses (upper 16 bits)
0 to 65535
DM1486
Set value error code
When an error
occurs, a
corresponding error
code 11 to 17 is
stored.
■ Data memories for motor drive
KVSKA Appendix.P65
08.3.11, 11:26 AM
173
See also other documents in the category KEYENCE Sensors:
- LR-TB2000 Series (12 pages)
- LR-TB5000 Series (12 pages)
- LR-ZB250AN/AP (4 pages)
- LR-ZB250AN/P (3 pages)
- LR-ZBxN/P Series (3 pages)
- LR-ZBxxB (3 pages)
- OP-85135 (1 page)
- PZ-G Series (2 pages)
- PZ-V/M (2 pages)
- PS-N10 Series (12 pages)
- PX-10 (10 pages)
- CZ-V21A(P) (10 pages)
- CZ-K1(P) (8 pages)
- CZ-V1 (8 pages)
- FS-N10 Series (6 pages)
- FS-N10 Series (116 pages)
- FS-N15CN (1 page)
- FU-93(Z) (2 pages)
- FU-V Series (2 pages)
- FS-V30 (6 pages)
- FU-A40 (1 page)
- NU/FS-N Series (16 pages)
- FS-V33(P) (8 pages)
- FS-V21 (4 pages)
- FS-V22 (4 pages)
- FS-V11(P) (4 pages)
- FS-V1(P) (4 pages)
- LV-N10 Series (12 pages)
- LV-N10 Series (112 pages)
- LV-S62 (1 page)
- OP-84350 (1 page)
- LV-SA (10 pages)
- LV-SB (12 pages)
- OP-87305 (1 page)
- LV Series (10 pages)
- LV-B102 (1 page)
- EV-108M(U) (1 page)
- EZ Series (1 page)
- EM Series (1 page)
- ES-M1(P) (3 pages)
- EX-V Series (120 pages)
- EX-500(W) Series (16 pages)
- GV Series (10 pages)
- IA Series (8 pages)
- LB-1000(W) (24 pages)