KEYENCE KV Series User Manual
Page 203

Appendices
2-179
1
Appendices
■ Samp09.ldr
Various timer circuits
Applicable models : All KV Series (KV-10 is used in the program.)
Description
: Three typical timer circuits are shown: On-delay, Off-delay and
One-shot timers.
■ Samp10.ldr
One-shot timer with adjustable set value by using Analog timer
Applicable models : All KV Series (KV-10 is used in the program.)
Description
: The set value of this one-shot timer can be adjusted using
Analog timer on the KV PLC.
■ Samp11.ldr
Setting value for internal counter by using BCD digital switch
Applicable models : All KV Series (KV-10 is used in the program.)
Description
: The set value of counter can be changed using external BCD
digital switch.
■ Samp12.ldr
Positioning control in KV-300 CPU (with return to home function)
Applicable models : KV-300
Description
: Performs trapezoid control and return to home using the posi-
tioning control function built into the KV-300 CPU unit.
■ Samp13.ldr
Direct memory sharing between KV-L2 units
Applicable models : KV-300 and KV-L2
Description
: Sets one KV-L2 as the parent station (no-procedure protocol
mode), sets the other KV-L2 as the child station (KV mode), and
reflects values of DMs changed in the parent station on the
child station.
■ Samp14.ldr
Convenient instruction to measure a pulse-to-pulse interval
Applicable models : All KV Series models (KV-10 is used in the program.)
Description
: Measures a pulse-to-pulse interval using ITVL instruction.
■ Samp15.ldr
Calculation of analog input mean value in KV-AN6
Applicable models : KV-300 and KV-AN6
Description
: Obtains the mean value of analog input values received by the
KV-AN6.