doepfer

System A - 100

MIDI-CV/SYNC Interface

A-190

9

CV CHAR.

This parameter sets the voltage control characteri-
stics
of the pitch CV output from the A-190, so that it’s
possible to drive both common types of analog synth -
older Korgs, Yamahas, etc., which have a linear re-
sponse (Hz / V), and Rolands, ARPs, Moogs, etc.,
which have a logarithmic response (1V / octave).

H

For use just with the A-100, the V / octave
response is all that is needed. The Hz / V
option is provided purely for connecting to
external synths which use that standard.

M

M

M

M

V / Octave :

PROG CHANGE 3

Hz / V :

PROG CHANGE 4

RETRIGGER

This parameter enables you to choose between single
and multiple triggering of the ADSR. With RETRIG-
GER on, every time a key is pressed, another gate
signal is sent
, even if (ie in legato playing) another
key is still held down at the time.

M

M

M

M

OFF :

PROG CHANGE 5

ON :

PROG CHANGE 6

H

This parameter can also be changed in per-
formance mode. If, even with RETRIGGER
ON, the gate isn’t reliably re-triggered, set a
higher value for the gate retrigger time in
CONFIG menu 5.