System a - 100, A-112, Doepfer – Doepfer A-100(~ 40 MB) User Manual
Page 197

doepfer
System A - 100
Sampler
A-112
7
Gate = low:
The module is waiting for gate = high; LED 3 is off
(see fig. 1 - a).
Gate = high:
When the gate level changes from low to high Play-
back is triggered and the audio signal in the memory
bank is played back. LED 3 is now on. Playback starts
at address 0 and continues until the last address (65
535) is reached and LED 3 turns off. Even if the gate
goes low before the end of the sampling memory is
reached the playback continues (see fig. 1 - b).
Only if the gate goes low and high again before the
end is reached the sample is retriggered, i.e. the
playback starts again at address 0 (see fig. 1 - c).
If the gate is still high when the end of the sample
memory is reached the playback stops (i.e. no loop if
gate remains high). For this purpose the loop mode is
used.
fig. 1: normal play mode
• Loop record mode
This mode is very similar to the normal record mode
(see above). The only difference to the normal re-
cord mode is that record continues when the end of
the sample memory is reached and the gate level is
still high.
A udio
Out
Gat e
a
c
Sample
b
5
5
5
5
6
6
6
6
7
7
7
7
Audio / Wave-CV In
Tune / CV
S1,
S2
Rec Loop
audio signal
sampling fre-
quency (only if
Gate = low)