A-149 /1, System a - 100, In- / outputs – Doepfer A-100(~ 40 MB) User Manual
Page 460: Doepfer

A-149 /1
RCV
System A - 100
doepfer
4
Fig.1: Probability distribution for different settings of "D"
H
The final value of D is the sum of the manual
control 5 and the external (attenuated) control
voltage applied to input %.
6
CV D
The external control voltage CVD fed into input ( is at-
tenuated with this control.
7
LED • 8 LED
The brightness of each LED is proportional to the
output voltage at the corresponding output / resp. (.
4. In- / Outputs
4.1 Quantized Random Voltages
!
CV N In
This socket is the Control Voltage input for the para-
meter "N".
"
Clk In
This socket is the Clock input for the Quantized Ran-
dom Voltages section. Each rising edge of this signal
causes the generation of a new random voltage at the
outputs § resp. $. Any clock or gate signal can be
used to control this input.
§
n+1
This socket outputs the random voltage with n+1 sta-
tes. The voltage range for this output is 0 to +5 V, the
voltage steps are 1.0 V (i.e. 1V quantization). This
corresponds to octave intervals when used to control
the pitch of a VCO.
$
2
n
This socket outputs the random voltage with 2
n
states.
The voltage range for this output is 0 to +5.25 V, the
voltage steps are 1/12 V (i.e. 1/12 V quantization).
This corresponds to semitone intervals when used to
control the pitch of a VCO.
H
äu
fig
ke
it
Zufallsspannung [V]
D = 5
D ~ 10
D ~ 0
H
äu
fig
ke
it
Zufallsspannung [V]
D = 5
D ~ 10
D ~ 0
output voltage
probability