beautypg.com

A-111, System a - 100, Doepfer – Doepfer A-100(~ 40 MB) User Manual

Page 164: Vco 2

background image

A-111

VCO 2

System A - 100

doepfer

10

Soft Sync
In contrast with hard sync, soft sync produces no
change in the waveform
of the slave VCO. The
master VCO simply forces the slave’s waveform direc-
tion changes to match its own.

That simply means that the slave VCO's frequency
f

S

is increased, to become an exact multiple of the

master VCO’s.

In fig. 14 you can see that the frequency of the
‘synced’ triangle wave f

R

is forced into being exactly

double that of the master VCO f

M

(or, to put it another

way: cycle T

M

is twice the length of cycle T

R

).

Soft Sync, because there is no change in the slave’s
actual waveform shape, can’t produce timbral variati-
ons. What it does instead is to lock two or preferably
more oscillators into a perfect harmonic relation
,
to produce a particular sort of timbre.

Fig. 14: Soft sync on the A-111

T

M

T

R

T

S

0V

0V

0V

Slave-Signal

Master-Signal

Soft-Sync-Signal