beautypg.com

A-156, System a - 100, Doepfer – Doepfer A-100(~ 40 MB) User Manual

Page 524

background image

A-156

Quantizer

System A - 100

doepfer

6

5. In / Outputs

!

CV In • % CV In

Socket ! and % are the

inputs for the quantizers 1

and 2 respectively. The control voltage to be quantized
is patched into these sockets.

"

CV Out • & CV Out

At

outputs " and & the quantized voltages appear.

§

Trig. In • / Trig. In

If a trigger signal is applied to the

trigger input § or /

the quantization process takes place during

low/high

transition of the trigger signal. If this is not desired
leave the socket un-connected. Quantization then ta-
kes place at the internal rate of about 500Hz.

The external trigger signals are scanned with a rate of
about 1kHz. Therefore the external trigger frequency
has to be less than 500Hz to avoid aliasing effects. In
practice this will be no restriction as normal quantiza-
tion rates are much lower (usually only a few Hz).

fig. 6: External triggered quantization

1

12

V

Trig.

In

CV

Out

CV

In