beautypg.com

System a - 100, A-176, Controls – Doepfer A-100(~ 40 MB) User Manual

Page 601: Outputs

background image

doepfer

System A - 100

Control Voltage Source

A-176

3

3. Controls

1

CV 1 • 3 CV 2

Controls 1 and 3 provide coarse adjustment of the
voltages at outputs ! and ", and § and $ respecti-
vely.

The range of controls 1 and 3 is approximately 5 V.

2

Fine • 4 Fine

Controls 2 and 4 provide precision adjustment of
control voltages CV 1 (at outputs ! and ") and CV 2
(at outputs § and $) respectively.

The range of controls 2 and 4 is approximately 0.1 V.

5

CV 3

This knob sets the control voltage CV 3, at output %.

The range of this control is approximately 5 V.

4. Outputs

!

CV 1 • " CV 1

These are the internally connected parallel outputs
for the first CV source, whose level is set by controls
1

and 2.

§

CV 2 • $ CV 2

These are the internally connected parallel outputs
for the second CV source, whose level is set by
controls 3 and 4.

%

CV 3

This is the output for the third CV source, whose
level is set by control 5.

H

The voltage range for each of the sources
is individually adjustable with jumpers on the
circuit board, either to 0 V - 5 V or symmetri-
cal around zero
(-2.5 V to +2.5 V).