Dell POWEREDGE M1000E User Manual
Page 189
2-159
Cisco Catalyst Blade Switch 3130 and 3032 for Dell Command Reference
OL-13271-03
Chapter 2 Cisco Catalyst Blade Switch 3130 and 3032 for Dell Cisco IOS Commands
energywise query
Defaults
The importance value is 1.
The power level is 10.
Command Modes
Privileged EXEC
Command History
Usage Guidelines
In the results from the sum keyword, the Responded total is not accurate. The Queried total is accurate
and is the total number of entities that respond to the query.
To power on or power off ports, enter the energywise query {keywords word,word,... | name name} set
level level command.
Caution
Use this query with care because it affects the entity on which you enter the command and
other domain devices that match the query criteria.
Examples
These examples show how to filter with the entity name.
Switch# energywise query name phone* collect usage
EnergyWise query, timeout is 3 seconds:
Host Name Usage
---- ---- -----
2.2.2.21 phone 0.0 (W)
2.2.2.21 phone 15.4 (W)
2.2.2.21 phoneA 0.0 (W)
2.2.2.22 phone 0.0 (W)
2.2.2.21 phoneB 0.0 (W)
2.2.2.22 phoneC 15.4 (W)
2.2.2.21 phone 0.0 (W)
2.2.2.23 phoneD 15.4 (W)
2.2.2.21 phone 0.0 (W)
Queried: 9 Responded: 9 Time: 0.26 seconds
Switch# energywise query name * sum usage
EnergyWise query, timeout is 3 seconds:
Total Usage
-----------
346.3 (W)
Queried: 147 Responded: 147 Time: 0.121 seconds
Release
Modification
12.2(50)SE
This command was introduced.