beautypg.com

Dell POWEREDGE M1000E User Manual

Page 189

background image

2-159

Cisco Catalyst Blade Switch 3130 and 3032 for Dell Command Reference

OL-13271-03

Chapter 2 Cisco Catalyst Blade Switch 3130 and 3032 for Dell Cisco IOS Commands

energywise query

Defaults

The importance value is 1.

The power level is 10.

Command Modes

Privileged EXEC

Command History

Usage Guidelines

In the results from the sum keyword, the Responded total is not accurate. The Queried total is accurate
and is the total number of entities that respond to the query.

To power on or power off ports, enter the energywise query {keywords word,word,... | name name} set
level
level command.

Caution

Use this query with care because it affects the entity on which you enter the command and
other domain devices that match the query criteria.

Examples

These examples show how to filter with the entity name.

Switch# energywise query name phone* collect usage

EnergyWise query, timeout is 3 seconds:

Host Name Usage

---- ---- -----

2.2.2.21 phone 0.0 (W)

2.2.2.21 phone 15.4 (W)

2.2.2.21 phoneA 0.0 (W)

2.2.2.22 phone 0.0 (W)

2.2.2.21 phoneB 0.0 (W)

2.2.2.22 phoneC 15.4 (W)

2.2.2.21 phone 0.0 (W)

2.2.2.23 phoneD 15.4 (W)

2.2.2.21 phone 0.0 (W)

Queried: 9 Responded: 9 Time: 0.26 seconds

Switch# energywise query name * sum usage

EnergyWise query, timeout is 3 seconds:

Total Usage

-----------

346.3 (W)

Queried: 147 Responded: 147 Time: 0.121 seconds

Release

Modification

12.2(50)SE

This command was introduced.