Dell POWEREDGE M1000E User Manual
Page 148
146
Configuring System Information
Figure 6-37. Optical Transceiver Diagnostics
The Optical Transceiver Diagnostics page contains the following fields:
• Interface — The port IP address on which the cable is tested.
•
Temperature — The temperature (C) at which the cable is operating.
• Voltage — The voltage at which the cable is operating.
•
Current — The current at which the cable is operating.
•
Output Power — The rate at which the output power is transmitted.
• Input Power — The rate at which the input power is transmitted.
•
Transmitter Fault — Indicates if a fault occurred during transmission.
•
Loss of Signal — Indicates if a signal loss occurred in the cable.
• Data Ready — Indicates the transceiver has achieved power up and data is ready.
Note: Finisar transceivers do not support the transmitter fault diagnostic testing. Fiber Optic analysis feature
works only on SFPs that support the digital diagnostic standard SFF-4872.
Displaying Optical Transceiver Diagnostics Test Results Table
1. Open the Optical Transceiver Diagnostics page.
2. Click Show All.
3. Select the desired unit from the drop-down menu.