beautypg.com

Transient suppression network – tsn (cont.), Transient suppression network fuse replacement – Rockwell Automation 7000L PowerFlex Medium Voltage AC Drive (C Frame) - Classic Control User Manual

Page 352

background image

6-8

Component Definition and Maintenance

7000L-UM300I-EN-P – June 2013

7000 “C” Frame

Transient Suppression

Network – TSN (cont.)

U

V

W

Drive Input Power

from

Line Terminals

Transient Suppression Network

Medium Voltage Input Fuses

Phase MOV

Suppressor

Ground MOV

Suppressor

Figure 6.6 – Simplified Wiring Diagram



Two sizes of fuses (5 kV, 7.2 kV) are available within the Transient
Suppression Network (TSN) located inside the connection cabinet. The
18-pulse drive contains three TSNs.

1. Ensure there is no power to the equipment.

A T T E N T I O N

A T T E N T I O N

To prevent electrical shock, ensure the main power
has been disconnected before working on the drive.
Verify that all circuits are voltage free using a hot
stick or appropriate voltage-measuring device.
Failure to do so may result in injury or death.


2. Fuses are held in a place with a fuse clip. To remove the fuse

pull firmly.

Transient Suppression

Network Fuse Replacement