6 acceleration and deceleration times tir,tif, Acceleration and deceleration times tir ,tif, Configuration – Lenze EDS4900U-REG User Manual
Page 97: 6 acceleration and deceleration times t

Configuration
7-6
48XX/49XXSHB0399
7.1.1.6
Acceleration and deceleration times T
ir
,T
if
Each acceleration or deceleration time refers to a speed change from 0 to n
max
(C011). The times T
ir
and T
if
to be set can be calculated as follows:
m a x
0
t i r
t i f
T i r
T i f
t
n
[ r p m ]
n
n
n 2
1
T = t
i r i r
n
n - n
2 1
m a x
T = t
i f i f
n
n - n
2 1
m a x
a c t
4900Str030
FIG 7-3
Calculation of acceleration and deceleration time
Here t
ir
and t
if
correspond to the times desired for the change from n
1
to n
2
and
vice versa.
The times T
ir
and T
if
calculated are setting values for the controller.
( Acceleration and deceleration time C012 and C013
The ramp function generator of the main set-value (n
set
or JOG set-value)is set via
the times T
ir
and T
if
under C012 and C013.
( Additonal acceleration and deceleration times
Alternaltively to the acceleration and deceleration times under C012 and C013,
additional T
ir
and T
if
times can be retrieved from the memory, for instance, to
change the drive acceleration from a certain speed on.
Programming of additional acceleration and deceleration times
Set the additional T
i
times in two steps. The selection under C100 is valid for a pair
of acceleration and deceleration times:
( Select additional acceleration/deceleration times under C100.
( Enter the required acceleration time under C101, and the deceleration time
under C103.
For several additional T
i
times repeat these two steps as often as required.
A maximum of 15 additional acceleration and deceleration times can be
programmed.
Show/Hide Bookmarks