Configuration – Lenze EDS4900U-REG User Manual
Page 218

Configuration
7-127
48XX/49XXSHB0399
Code
Possible settings
Name
Code
Info
Selection
Lenze
Name
C069
Controller state
Bit
Meaning
0
Operation error
1
Communication error
2
Operating mode was changed
3
Control via LECOM active
4
Control via terminals active
5
Controller reset (CCr fault)
6
not assigned
7
Controller enable
8 bit status information
Only readable via LECOM. The signals are
described in the LECOM-A/B protocol.
C070
V
pn
of the speed
controller
8
1
{1}
1000
Gain adjustment of the speed controller:
1.With low motor speed, increase V
pn
until
the drive starts to oscillate (high
frequency).
2.Reduce V
pn
, until the drive runs
smoothly.
[C071*] T
nn
of the speed
controller
400 ms 20 ms
{10 ms}
2000 ms
9999 ms
Integral action time of the speed controller
T
nn
= 9999 ms: I-component switched-off
(only when controller is inhibited)
C072*
K
dn
of the speed
controller
0
0
¼V
pn
{0.1}
5.0
¼V
pn
Differential component of the speed
controller
C077*
V
pl
of the field
controller
1.0
0.1
{0.1}
5.0
Gain adjustment of the field controller
C078*
T
nl
of the field
controller
300 ms 70 ms
{10 ms}
2000 ms
Integral action time of the field controller
C079*
PT1 element
Time constant
for field
controller
attenuation
140 ms 30 ms
{10 ms}
9000 ms
The larger the time constant, the larger
the decoupling between armature and
field circuits.
C081*
Rated motor
power
6.7 kW 0.0 kW
{0.1 kW}
10.0 kW
10kW
{1kW}
1000kW
See motor nameplate
C083
¤ Rated field
current
0A
0 A
{0.01 A}
30.0 A
Rated current depends on the controller:
0A/0.1A ... 3.5A
(4902, 4903)
0A/0.3A ... 10A
(4904 - 4907)
0A/0.3A ... 15A
(4X08)
0A/0.3A ... 30A
(4X09 - 4X13)
Data on the motor nameplate are
setpoints for the field current. With very
low field currents an auxiliary starting
circuit should be provided.
C084*
¤ CW/CCW
armature time
constant
10 ms
0 ms
{5 ms}
30 ms
Adaption of the current controller to
compensated and uncompensated motors
0 ms = adaption not active
C085*
¤ Thermal motor
time constant
1.0min 1.0 min
{0.1 min}
100.0 min
Required for ”I
2
¼
t monitoring” (motor
protection)
C087
¤ Rated motor
speed
3000
rpm
300 rpm
{1 rpm}
5000 rpm
See motor nameplate