3 slave for digital frequency cascade, Phase controller, Configuration – Lenze EDS4900U-REG User Manual
Page 137

Configuration
7-46
48XX/49XXSHB0399
7.3.3
Slave for digital frequency cascade
Purpose
With configuration C005 = -72- for the set-value cascade
( the phase control which is connected to the speed controller will be
activated
( the set-value path is changed to digital frequency coupling for speed ratio
synchronism.
4900Str044
X 7
X 5
X 8
X 1
X 9
S W I
R
X 7
X 8
X 5
R
X 7
X 8
X 5
F a c t o r
R
j
, n - c t r l .
E n c o d e r
o u t p u t
R e s o l v e r
I n c r e m e n t a l
e n c o d e r
M a s t e r d r i v e w i t h
m a s t e r i n t e g r a t o r
F a c t o r
j
, n - c t r l
E n c o d e r
o u t p u t
R e s o l v e r
S l a v e 1
j
, n - c t r l .
E n c o d e r
o u t p u t
R e s o l v e r
S l a v e 2
FIG 7-17
Connection diagram for the configuration of the digital frequency cascade
Features
( Only resolver feedback possible
( With a cascading factor evaluation of the set-value
(numerator/denominator) possible for the digital frequency output and thus
for all following drives adjustable via LECOM, motor potentiometer or
analog terminal
( Another evaluation of the set-value with a factor (numerator/denominator)
for the corresponding slave (gearbox adaptation). Adjustable via LECOM,
motor potentiometer or analog terminal
( External torque limitation possible
( The QSP or RFR function in the individual drive do not influence the
set-value of the cascade
( Influence possible via codes for phase trimming and speed correction (via
LECOM, motor potentiometer, analog termina or signal source (C145))
( Following error limit adjustabel via code
( TRIP when reaching the phase controller limit
( Speed limit = 1.8 ¼ C011
( Phase controller influence of 0 (0 = deactivated) adjustable up to 1.00
( No alternative set-value conditioning available (JOG, additional set-value,
set-value integrator, ...)