Operating modes, Configuration – Lenze EDS4900U-REG User Manual
Page 195

Configuration
7-104
48XX/49XXSHB0399
Code
Name
Possible settings
Code
Name
Lenze Selection
Info
C119*
¤ Selection of
monitoring
function
-15-
OC5
-16-
OC6
-22-
OUE
-31-
LU1
-32-
LU
-41-
LF
-42-
OF
-50-
OH
-61-
CE0
-70-
U15
-80-
SP
-81-
Sd1
-82-
Sd2
-83-
Sd3
-84-
Sd4
-85-
Sd5
-91-
EEr
-93-
dEr
-94-
ACI
-96-
FCI
-153-
P03
-163-
P13
-69-
CE9
I
¼t overload (controller protection)
I
2
¼t overload (motor protection)
Mains overvoltage
Phase fault
Mains undervoltage
Mains underfrequency f
Mains
< 47Hz
Mains overfrequency f
Mains
> 63Hz
Overtemperature heat sink
Communication error (automation
interface)
15V failure
Wrong signal source polarity
Tacho short circuit/interruption
Open circuit of resolver
Encoder fault at X5
Encoder fault at X9
Defective setpoint encoder
Ext. TRIP terminal
Motor blocked
Interruption of armature circuit
Interruption of field circuit
Following error
Angle overflow
Communication error (serial interface)
[C120*] Change of
monitoring
function
-0-
TRIP
-1-
Warning
-2-
Message with pulse inhibit
-3-
Message without pulse inhibit
-4-
Switched-off
The important monitoring functions are set
according to the change of configuration
under C005.
C123
Current
threshold
for blocking
protection
for C124
0.95
I
rated
0 A
{0.1A}
100 A
100 A
{1 A}
3600 A
Rated current depends on the controller:
0 ... 87A
(4902)
0 ... 135A
(4903)
0 ... 270A
(4904)
0 ... 450A
(4905)
0 ... 720A
(4906)
0 ... 900A
(4907)
0 ... 1200A
(4X08)
0 ... 1800A
(4X09)
0 ... 2520A
(4X11)
0 ... 3600A
(4X12)
0 ... 4050A
(4X13)
See motor nameplate
C124*
Blocking
time
60 s
1 s
{1 s}
100 s
Motor standstill time until fault message is
activated
Show/Hide Bookmarks