Configuration – Lenze EDS4900U-REG User Manual
Page 226

Configuration
7-135
48XX/49XXSHB0399
Code
Possible settings
Name
Code
Info
Selection
Lenze
Name
C148
Additional
torque value 1
0
-100.0 % M
max
{0.1%}
+ 100.0 % M
max
-200 % M
max
{1%}
+ 200 % M
max
Display only with terminal control. If the
terminal control is deactivated, the actual
terminal value will be accepted for
opera tion. Armature setting range: 100 %
M
max
correspond to 100 % I
max
(C022,
C023)
C149
Additional
torque value 2
0
-100.0 % M
max
{0.1%}
+ 100.0 % M
max
-200 % M
max
{1%}
+ 200 % M
max
Display only with terminal control. If the
terminal control is deactivated, the actual
terminal value will be accepted for
opera tion. Armature setting range: 100 %
M
max
correspond to 100 % I
max
(C022/C023)
C151*
FDO
Status
Bit
Free digital output
0
FDO 1
...
11
FDO 12
12
Relay output
C151 indicates the states of the digital
outputs as decimal or binary values. The
polarity reversal under C118 is not
considered.
[C180*] 4Q/2Q
operation
-0-
4Q operation (49XX)
-1-
2Q operation (48XX)
Important for controller type 48XX:
Controllers must only be operated with
C180 = -1-!
Fault PR sets C180 = -0-. It is absolutely
necessary to set C180 = -1- before
commissioning.
C182*
T
i
time of the
S-shape
ramp function
generators
20.0 s 0.01 s
{0.01s}
1 s
1s
{0.1s}
10s
10s
{1s}
50s
T
i
time for the S-shape ramp function
generator of the main setpoint
C183
Origin of
controller inhibit
Display
Origin of ctrl inhibit
Terminal or term.
Terminal
Keypad or kp
Keypad (STP key)
LECOM1 or L1
LECOM1 interface
Aut.int. (AIF)
Automation / fieldbus interface
(module, InterBus, PROFIBUS, ...)
oth. src. Other source
or o.s. Release: TRIP or message
Information: C065, C067
Display: Source which has inhibited the
controller
C185
Motor power
-500.0 kW
{0.1 kW}
500.0 kW
Display: actual motor power
C186
Motor torque
-999 Nm
{1 Nm}
999 Nm
Display: actual motor torque
C187
Field current
setpoint
0.00 A
{0.01 A}
50.0 A
Display: actual field current setpoint
C188
Actual field
current
0.00 A
{0.01 A}
50.0 A
Display: actual field current value
C189
Mains
frequency
0.0 Hz
{0.1 Hz}
100.0 Hz
Display: actual mains frequency
C190*
¤ Arithmetic
block 1
1
-0-
Output = C046
-1-
Output = C046 + C049
-2-
Output = C046 - C049
-3-
Output = C046
¼ C049
-4-
Output = C046 / |C049|
-5-
Output = C046 / (100% - C049)
C191*
¤ Arithmetic
block 2
1
-0-
Output = C338
-1-
Output = C338 + C339
-2-
Output = C338 - C339
-3-
Output = C338
¼ C339
-4-
Output = C338 / |C339|
-5-
Output = C338 / (100% - C339)