Table of attributes, Configuration – Lenze EDS4900U-REG User Manual
Page 224

Configuration
7-133
48XX/49XXSHB0399
Code
Possible settings
Name
Code
Info
Selection
Lenze
Name
C145*
¤ Input selection:
Analog signal
1
-1-
Input terminals X1/1, X1/2
-2-
Input terminals X1/3, X1/4
-3-
Input terminal X1/6
-4-
Input terminal X1/8
-5-
Digital frequency input X5
-6-
Digital frequency input X9
-7-
Resolver
-8-
Motor potentiometer output
-9-
Output process controller
-10-
Output arithmetic block 2 output 1
-11-
Fixed setpoint output
-12-
Output arithmetic block 2 output 2
-13-
Output dead band element output 1
-14-
Output dead band element output 2
-15
Output DT1 element output 1
-16
Output DT1 element output 2
-17-
Output absolute value generator output 1
-18-
Output absolute value generator output 2
-19-
Output limiting element 1 output 1
-20-
Output limiting element 1 output 2
-21-
Output PT1 element output 1
-22-
Output PT1 element output 2
-23-
Output arithmetic block 3 output 1
-24-
Output arithmetic block 3 output 2
-25-
Output addition block 1 output 1
-26-
Output addition block 1 output 2
-27-
Output addition block 2 output 1
-28-
Output addition block 2 output 2
-29-
n
act
from C382
-30-
n
set
from C050
-31-
Deviation at n-controller (xw)
-32-
Deviation at process controller (xw)
-33-
Ramp function generator output
-34-
n-controller output
-35-
Square-wave generator
-36-
Deviation at angle controller
-37-
RFG output of process controller setpoint
conditioning
-38-
RFG output of process controller evaluation
-39-
AIF process controller setpoint
-40-
Output limiting element 2 output 1
-41-
Output limiting element 2 output 2
-42-
Output comparator 1
-43-
Output comparator 2
The functions set under C146 can be
assigned to the input sources under
C145. Double assignment is not possible.
The function selected last is always
assigned to the input.
C145 = -1-, -2-, -3-, -4-, -5-, -6-:
Determine the priority for these inputs
under C147.
If C005 (configuration) is changed:
The freely selected assignments are
overwritten with a configuration-
dependent basic assignment. If necessary,
reassign functions.