Additional control functions, Additional torque values, Configuration – Lenze EDS4900U-REG User Manual
Page 173

Configuration
7-82
48XX/49XXSHB0399
Addition 1:
Code
Name
Possible settings
Code
Name
Lenze Selection
Info
C610*
Input 1,
addition
block 1
0%
-100.0 %
{0.1 %}
100.0 %
-200 %
{1 %}
+ 200 %
If an analog signal source (C145/C146) is
assigned, the parameter will be displayed
only.
C611*
Input 2,
addition
block 1
0%
-100.0 %
{0.1 %}
100.0 %
-200 %
{1 %}
+ 200 %
If an analog signal source (C145/C146) is
assigned, the parameter will be displayed
only.
C612*
Input 3,
addition
block 1
0%
-100.0 %
{0.1 %}
100.0 %
-200 %
{1 %}
+ 200 %
If an analog signal source (C145 / C146) is
assigned, the parameter will be displayed
only.
Addition 2:
Code
Name
Possible settings
Code
Name
Lenze Selection
Info
C614*
Input 1,
addition
block 2
0%
-100.0 %
{0.1 %}
100.0 %
-200 %
{1 %}
+ 200 %
If an analog signal source (C145/C146) is
assigned, the parameter will be displayed
only.
C615*
Input 2,
addition
block 2
0%
-100.0 %
{0.1 %}
100.0 %
-200 %
{1 %}
+ 200 %
If an analog signal source (C145/C146) is
assigned, the parameter will be displayed
only.
C616*
Input 3,
addition
block 2
0%
-100.0 %
{0.1 %}
100.0 %
-200 %
{1 %}
+ 200 %
If an analog signal soucre (C145 / C146) is
assigned, the parameter will be displayed
only.