Code
Possible settings
Name
Code
Info
Selection
Lenze
Name
C610*
Input 1, addition
block 1
0%
-100.0 %
{0.1 %}
100.0 %
-200 %
{1 %}
+ 200 %
If an analog signal source (C145/C146) is
assigned, the parameter will be displayed
only.
C611*
Input 2, addition
block 1
0%
-100.0 %
{0.1 %}
100.0 %
-200 %
{1 %}
+ 200 %
If an analog signal source (C145/C146) is
assigned, the parameter will be displayed
only.
C612*
Input 3, addition
block 1
0%
-100.0 %
{0.1 %}
100.0 %
-200 %
{1 %}
+ 200 %
If an analog signal source (C145/C146) is
assigned, the parameter will be displayed
only.
C614*
Input 1, addition
block 2
0%
-100.0 %
{0.1 %}
100.0 %
-200 %
{1 %}
+ 200 %
If an analog signal source (C145/C146) is
assigned, the parameter will be displayed
only.
C615*
Input 2, addition
block 2
0%
-100.0 %
{0.1 %}
100.0 %
-200 %
{1 %}
+ 200 %
If an analog signal source (C145/C146) is
assigned, the parameter will be displayed
only.
C616*
Input 3, addition
block 2
0%
-100.0 %
{0.1 %}
100.0 %
-200 %
{1 %}
+ 200 %
If an analog signal source (C145/C146) is
assigned, the parameter will be displayed
only.
C620*
Gain dead band
element
1.00
-10.00
{0.01}
+ 10.00
C621*
Dead band,
dead band
element
1.0 %
0.0 %
{0.1 %}
100.0 %
C622*
Input, dead
band element
0%
-100.0 %
{0.1 %}
100.0 %
-200 %
{1 %}
+ 200 %
Display parameter only
C630*
Limiting
element 1
upper limit
100 % -100.0 %
{0.1 %}
100.0 %
-200 %
{1 %}
+ 200 %
C630 must be higher than C631!
C631*
Limiting
element 1
lower limit
-100 % -100.0 %
{0.1 %}
100.0 %
-200 %
{1 %}
+ 200 %
C631 must be lower than C630!
C632*
Input, limiting
element 1
0 %
-100.0 %
{0.1 %}
100.0 %
-200 %
{1 %}
+ 200 %
Display parameter only
C635*
Limiting
element 2
upper limit
100 % -100.0 %
{0.1 %}
100.0 %
-200 %
{1 %}
+ 200 %
C635 must be higher than C636!
C636*
Limiting
element 2
lower limit
-100 % -100.0 %
{0.1 %}
100.0 %
-200 %
{1 %}
+ 200 %
C636 must be lower than C635!
C637*
Input, limiting
element 2
0 %
-100.0 %
{0.1 %}
100.0 %
-200 %
{1 %}
+ 200 %
Display parameter only
C640*
PT1 element
Time constant
20ms
0.01 s
{0.01 s}
1 s
1 s
{0.1 s}
10 s
10 s
{1 s}
50 s
Show/Hide Bookmarks