Configuration – Lenze EDS4900U-REG User Manual
Page 214

Configuration
7-123
48XX/49XXSHB0399
Code
Possible settings
Name
Code
Info
Selection
Lenze
Name
C029
¤ Automatic
adjustment for
C025
C025 = -10-, -11-:
Adjustment of the digital frequency inputs X5, X9
-100.0%
{0.1%}
100.0%
Automatic adjustment only possible, if X5
or X9 are not selected as acutal speed
inputs:
1.Display of actual output value.
2.Enter required output value.
3.C027 displays the calculated gain
factor.
C025 = -12-
Adjustment of the resolver
-100.0%
{0.1%}
100.0%
Automatic adjustment is only possible, if
the resolver is not used as a speed
feedback system:
1.Display of actual output value.
2.Enter required output value.
3.C027 displays the calculated gain
factor.
C030
¤ Constant for the
digital frequency
output
1
-0-
8192 increments / revolution
-1-
4096 increments / revolution
-2-
2048 increments / revolution
-3-
1024 increments / revolution
-4-
512 increments / revolution
-5-
256 increments / revolution
Number of increments per revolution for
the digital frequency output
C032*
Ratio numerator 0.1000 -3.2767 {0.0001}
3.2767
Ratio numerator for configurations with
digital frequency
If an analog signal source is assigned
(C145/146), only the parameter will be
displayed.
C033*
Ratio
denominator
0.1000 0.0001
{0.0001}
3.2767
Ratio denominator for configurations with
digital frequency
C034*
¤ Master current
0
-0-
i
master
= -20 mA ... + 20 mA
-1-
I i
master
|= 4 mA ... 20mA
For master current input, the switch S3/1
must be set to ON.
C034 = -1-:
If i
master
< 2mA, the monitoring message
Sd5 will be displayed.
C038
¤ Input selection:
JOG setpoint
1
-1-
Selection JOG1
-2-
Selection JOG2
...
-15-
Selection JOG15
Select JOG setpoint to be set under C039.
C039
JOG speed for
C038
-100.0 % n
max
{0.1 %}
+ 100.0 % n
max
100.0%
JOG1
75.0%
JOG2
50.0%
JOG3
25.0%
JOG4
0.0%
JOG5
..
...
0.0%
JOG15
Enable JOG setpoints via the digital inputs
or via C045.
C040
Controller
enable
-0-
Controller inhibited
-1-
Controller enabled
Input only via LECOM1 or LECOM2. C183
indicates the source which has inhibited
the controller.
C041
¤ CW/CCW
direction of
rotation
-0-
Main setpoint not inverted
-1-
Main setpoint inverted
Input only with control via keypad or
interface.
Display only with terminal control.
C042
¤ Quick stop
-0-
No quick stop
(corresponds to X2/21 or X2/22 = HIGH)
-1-
Quick stop active
(corresponds to X2/21 and X2/22 = LOW)
Drives decelerates to standstill following the
quick-stop ramp C105.
Input only with control via keypad or
interface.
Display only with terminal control.