3 rated data, 1 mains voltage 400v, Rated data – Lenze EDS4900U-REG User Manual
Page 32: Mains voltage 400v, Technical data

Technical Data
3-4
48XX/49XXSHB0399
3.3
Rated data
3.3.1
Mains voltage 400V
( Controllers 4902 to 4907 (4Q controllers)
Type
4902
4903
4904
4905
4906
4907
Order No.
EVD 4902-E EVD 4903-E EVD 4904-E EVD 4905-E EVD 4906-E EVD 4907-E
Output power
1)
P
el
[kW]
6.7
10.5
23.1
46.2
84
105
Mains voltage
V
mains
3
¼ 340...460 V~ á0%, 50...60Hz
Armature voltage
V
A
420V if V
mains
= 400V (1.05
¼V
mains
)
Rated armature current
(continuous operation)
I
Arated
[A]
16
25
55
110
200
250
Maximum current
(short-time operation)
I
Amax
[A]
29
45
90
150
240
300
Field voltage
2)
V
F
V
Fmax
= 0.875
¼V
L1
-
L3
Max. field current,
controlled
I
F
[A]
3.5
10
Power loss
3)
P
loss
[W]
60
108
185
288
577
650
Ambient temperature in
operation
T
amb
[
C]
0...+ 45
0...+ 35
4)
Weight approx.
[kg]
9,2
13,1
13,8
18
22
23
( Controllers 4908 to 4913 (4Q controllers)
Type
4908
4909
4911
4912
4913
Order No.
EVD 4908-E
EVD 4909-E
EVD 4911-E
EVD 4912-E
EVD 4913
Output power
1)
P
el
[kW]
139
210
294
420
504
Mains voltage
V
mains
3
ô 340 ... 460 V~ á0%, 50...60Hz
Armature voltage
V
A
420 V if V
mains
= 400V (1.05
ôV
mains
)
Rated armature current
(continuous operation)
I
Arated
[A]
330
500
700
1000
1200
Maximum current (short-time
operation)
I
Amax
[A]
400
600
840
1200
1350
Field voltage
2)
V
F
V
Fmax
= 0,875
¼V
L1
-
L3
Max.field current, controlled
I
F
[A]
15
30
Power loss
3)
P
loss
[W]
840
1220
2100
2850
3400
Ambient temperature in
operation
T
amb
[
C]
0...+ 35
4)
Weight approx.
[kg]
28
28
60
60
60
Show/Hide Bookmarks