2 fault analysis with the history buffer, 1 structure of the history buffer, Fault analysis with the history buffer – Lenze EDS4900U-REG User Manual
Page 248: Structure of the history buffer, Troubleshooting and fault elimination

Troubleshooting and fault elimination
8-3
48XX/49XXSHB0399
8.2
Fault analysis with the history buffer
With the history buffer, faults can be traced. The fault messages are stored in the
history buffer in the order of their occurrence.
8.2.1
Structure of the history buffer
( The history buffer has eight memory locations, which can be retrieved
- under C065, C066 and C067 at the operating unit
- via the LECOM interface under codes C161 to C168 for TRIP messages.
( The first memory location is written only after the elimination or
acknowledgement of the active fault. The eighth from last fault is eliminated
in the history buffer and can no longer be read.
( The memory locations 1-8 contain information about the last to eighth from
last fault.
Code
C0168
C063
Active message
C066
Active warning
C067
Active TRIP
C161
Memory location 1
C162
Memory location 2
C163
Memory location 3
C164
Memory location 4
C165
Memory location 5
C166
Memory location 6
C167
Memory location 7
C168
Memory location 8
Show/Hide Bookmarks