Configuration – Lenze EDS4900U-REG User Manual
Page 227

Configuration
7-136
48XX/49XXSHB0399
Code
Possible settings
Name
Code
Info
Selection
Lenze
Name
C192*
¤ Input selection:
Fixed setpoint
1
-1-
Selection fixed setpoint 1
-2-
Selection fixed setpoint 2
...
-15-
Selection fixed setpoint 15
It is possible to set up to 15 setpoints with
freely selectable references:
1.Select fixed setpoint under C192.
2.Assign value under C193.
3.Enable via the digital inputs or C194.
C193*
Setpoint for
C192
-100.0 %
{0.1 %}
+ 100.0 %
100.0%
Fixed setpoint 1
75.0%
Fixed setpoint 2
50.0%
Fixed setpoint 3
25.0%
Fixed setpoint 4
0.0%
Fixed setpoint 5
...
0.0%
Fixed setpoint 15
C194*
¤ Enable fixed
setpoint
0
-0-
Free input is active
-1-
Fixed setpoint 1 is active
...
-15-
Fixed setpoint 15 is active
C195*
Delay
between
’engage brake’
and controller
inhibit
9999 s 0.00s
{0.01 s}
1s
1s
{0.1s}
10s
10s
{1s}
250s
9999 s
Delay between signal ’engage brake’ and
automatic controller inhibit
9999 s:
Unlimited delay, controller will not be
inhibited.
C196*
Delay between
’setpoint
integrator free’
and quick stop
0.00s
0.00 s
{0.01 s}
1 s
1s
{0.1s}
10s
10s
{1s}
100s
100s
{10s}
250s
Delay between reset of the quick stop
function and enable of the main setpoint
integrator
[C197*] Sign of the
torque selection
0
-0-
Sign is determined by the torque setpoint
-1-
positive sign
-2-
negative sign
Sign of the torque selection between reset
of QSP and enable of the setpoint
integrators
[C198*] Enable actual
speed filter
0
-0-
Filter not active
-1-
Filter active
C199*
Time constant
act. speed filter
10ms
8ms
{1ms}
100ms
C200*
Software
identification
String format: ”33S4902M_61000”
Display of the software version only via
interface.
C220*
Acceleration
time T
ir
of the
additional
setpoint
0.00 s 0.00 s
{0.01 s}
1 s
1 s
{0.1 s}
10 s
10 s
{1 s}
100 s
100 s
{10 s}
990 s
C221*
Deceleration
time T
if
of the
additional
setpoint
0.00 s 0.00 s
{0.01 s}
1 s
1 s
{0.1 s}
10 s
10 s
{1 s}
100 s
100 s
{10 s}
990 s
C222*
V
p
process
controller
1
0.1
{0.1}
10
10
{1.0}
500
Gain of the process controller
[C223*] T
n
process
controller
400 ms 20 ms
{1ms}
20000 ms
9999 ms
T
n
= 9999 ms: I-component switched-off
(only when controller is inhibited)
C224*
K
d
process
controller
0.0
0.0
¼ V
pn
{0.1
¼ V
pn
} 5.0
¼ V
pn
Differential component of the process
controller
[C230*] Control mode
for the override
field control
0
-0-
Limitation of the armature voltage
-1-
Control of the armature voltage
Field weakening must be permitted under
C231.