4 basics for operation, 1 parameter change via code, Configuration – Lenze EDS4900U-REG User Manual
Page 202

Configuration
7-111
48XX/49XXSHB0399
7.8.4
Basics for operation
7.8.4.1
Parameter change via a code
Note!
If changed parameter sets are required after mains switching, they must be stored
(chapter 7.8.4.3).
Each code with parameters, which can be changed, is factory set. Depending on
the code there are three possibilities to change a parameter.
Each possibilities is explained by means of an example.
Direct acceptance (on-line)
The controller accepts the changed parameter immediately.
1. Select a code using
s or t .
2. Change to the parameter level using PRG.
3. Select a parameter using
s or t .
The controller accepts the changed parameter immediately.
This is also possible during operation of the drive.
4. Change to the code level using PRG.
Code level
Parameter level
C
0
E
P
m
Code
Parameter
Un i t
0 1 1
r p m
0
0
3
N
a x
S
E D
PRG
C
0
E
P
m
C ode
Parameter
Un i t
0 1 1
r p m
0
0
3
N
a x
S
E D
Change a parameter
with
s or t
C
0
E
P
m
C ode
Parameter
Un i t
0 1 1
r p m
N
a x
S
E D
2 7 5
PRG
C
0
E
P
m
C ode
Parameter
Un i t
0 1 1
r p m
N
a x
S
E D
2 7 5
Show/Hide Bookmarks
- ESMD smd tmd remote keypad (4 pages)
- EPM Programmer EEPM1RA (114 pages)
- ESMDC (36 pages)
- SMD Frequency Inverter 0.37kW-22kW (116 pages)
- SMD Frequency Inverter: Basic I/O with CANopen 0.25kW-4.0kW (36 pages)
- SMD 0-25kW-4-0kW (112 pages)
- smd Series Drives (32 pages)
- ESV SMV remote keypad H0 (2 pages)
- ESV SMV remote keypad H1 (2 pages)
- SV SMV additional I-O module (14 pages)
- EEPM1RA EPM (26 pages)
- SMVector RS-485 LECOM (29 pages)
- E84AYM10S (4 pages)
- E84AYCET EtherCAT MCI module (109 pages)
- EZAMBKBM (6 pages)
- E84AYCEC (89 pages)
- ERBPxxxRxxxx Brake resistor 200W-300W (134 pages)
- E84AYCPM (115 pages)
- E84AYCEO (165 pages)
- E84AYCER (94 pages)
- E84AVSCx 8400 StateLine C (76 pages)
- EZVxxxx-000 Power supply unit AC 230V 5A-20A (62 pages)
- E84AYCIB (75 pages)
- E82ZWBRB (48 pages)
- EZVxx00−001 Power supply unit AC 400V 5A-20A (64 pages)
- E82ZWBRE (64 pages)
- EZAEBK1001 (94 pages)
- E94AYAE SM301 (134 pages)
- E94AYAE SM301 (74 pages)
- E94AYAE SM301 (140 pages)
- E94AZPS (114 pages)
- E94AYCIB (78 pages)
- E94AYCIB (124 pages)
- E94AZEX100 (84 pages)
- EZS3-xxxA200 Sinusoidal filter 115-150A (44 pages)
- E94AZHA0051 (104 pages)
- E94AZCDM030 (72 pages)
- EZS3-xxxA200 Sinusoidal filter 180-480A (74 pages)
- E94AYCCA (114 pages)
- E94AYCCA (188 pages)
- E94AZHB0101 (104 pages)
- E94AYCPM (125 pages)
- E94AYCPM (114 pages)
- E94AYCET (140 pages)
- E94AYCET (103 pages)