Configuration – Lenze EDS4900U-REG User Manual
Page 126

Configuration
7-35
48XX/49XXSHB0399
Example for the assignment of a monitor output terminal 62 to the terminal signal
C046 ”main set-value”.
( C110 = -1- Monitor output term. 62
( C111 = -1- Main set-value C046
6 2
6 3
C 1 1 0
C 1 1 1
+
C 1 0 8
C 1 0 9
N o s i g n a l
T e r m i n a l s e l e c t i o n
S i g n a l s e l e c t i o n
M a i n s e t p o i n t C 0 4 6
I n p u t s e t p o i n t i n t e g r a t o r
I
O f f s e t
G a i n
F a c t
4900Str039
FIG 7-12
Parameter assignment of the monitor outputs
A D/A conversion is possible using the codes C272 and C273, if the code is
assigned to an analog output. The digital value written via interface occurs as
voltage signal, which has been converted at the programmable monitor output.
Special features of the digital frequency output
If the configuration is changes, the digital frequency output is assigned according
to the basic assignment. The signal ”n
act
” is output under C005 =-1X- and -4X-.
In all other configuration, the signal ”n
set
” is assigned to the output. The following
table informs about the basic assignment of the digital frequency ouputs after
configuration changeover and the adaptation of the output frequency. If
necessary, this assignment can also be changed according to the requirements.