Selection aid – Lenze EDS4900U-REG User Manual
Page 304

Selection aid
15-12
48XX/49XXSHB0399
Parameter setting
Code
Input
Description
Input according to motor nameplate
C083
xxx A
Rated field current
C084
xxx ms
Armature-time constant
C088
xxx A
Rated motor current
C090
xxx V
Rated motor voltage
Freely assignable analog inputs
C145
-4-
Input selection term. 8
C146
-15-
Arithmetic block2 input 1
C145
-3-
Input selection term. 6
C146
-16-
Arithmetic block2 input 2
C145
-10-
Input selection arithmetic block output
C146
-1-
Main set-value C046
C145
-9-
Input selection process controller output
C146
-3-
Additional set-value C049
C145
-1-
Input selection term. 1.2
C146
-7-
Actual process controller value
Freely assignable digital inputs
C112
-3-
Input selection E3
C113
-32-
Process controller evaluation
C112
-5-
Input selection E5
C113
-31-
Process controller I component off
Arithmetic block
C191
-4-
Output = input 1 / input 2
Convert distance
@ diameter
C025
-3-
Input selection term. 6
C026
Offset for distance a = -xxx mV
C027
2.000
Evaluation for diameter
Adjustment of speed controller
C011
xxxx rpm
Enter max. speed
C025
-2-
Select adjustment at terminals 3 and 4
C029
n
act
Adjust speed
process controller
C330
xxx %
Select position set-value
C331
xxx %
Evaluation of process controller output
Application parameters
C022, C023
xxx A
Maximum motor current
C019
xxxx rpm
Set threshold n
act
= 0
C070
V
pn
At high inertias, adapt n - controller gain
C222
V
pp
Optimise process controller
Save parameter
C003
Save parameter set