Configuration – Lenze EDS4900U-REG User Manual
Page 114

Configuration
7-23
48XX/49XXSHB0399
Code
Possible settings
Name
Code
Info
Selection
Lenze
Name
[C115*] Priority for
C112
-0-
Deactivate terminal function, if terminal control
is switched-off under C001. (X2/E4, E5)
-1-
Terminal function remains active, if terminal
control is switched-off under C001. (X2/E1, E2,
E3)
C136*
FDI
Status
Bit
Free digital input
0
FDI 1
...
3
FDI 4
4
FDI 5
Only readable via LECOM.
C136 indicates the states of the digital
inputs as decimal or binary value. The
change of polarity under C114 is
considered in C136.
Example for enable of additional T
i
time for terminal E2
( C112 -2- Digital input X2/E2
( C113 -1- Enable additional T
i
times
C 1 1 2
E 1
E 2
E 3
E 5
C 1 1 5
C 1 1 4
C 1 1 3
C 0 0 1
O p e r a t i n g m o d e
P r i o r i t y
L e v e l
T e r m i n a l s e l e c t i o n
S i g n a l s e l e c t i o n
N o s i g n a l
A d d i t i o n a l T i - t i m e s
J O G s e t p o i n t s
R F G z e r o
4900Str035
FIG 7-8
Parameter assignment for digital inputs
Except the functions ”Enable JOG set-values”, ”Enable additional acceleration and
deceleration times”, ”Enable fixed set-values” and ”Select parameter set”, each
function can only be assigned to one terminal. An already assigned function will be
overwritting by re-assigning the input.
A function, which is already assigned to an input, can only be assigned to another
terminal, if the input used before is assigned with a new function.
LECOM code for FDI
The states of FDI (E1 ... E5) can be displayed in binar format in C136 or they can
be read out in HEX format via the LECOM interface.
FDI assignment in C136:
Bit 15
.........
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
not assigned
FDI5
FDI4
FDI3
FDI2
FDI1