2 general data / application conditions, General data / application conditions, Technical data – Lenze EDS4900U-REG User Manual
Page 31

Technical Data
3-3
48XX/49XXSHB0399
3.2
General data / application conditions
Field
Values
Type of protection
IP20 to DIN 40050, steel sheet housing
Permissible humidity
Relative humidity 90%, no condensation
Temperature ranges
Storage
-25
C...+ 55 C
Transport
-25
C...+ 70 C
Influence of the installation height
h
$ 1000m : 100%rated armature current
h
$ 2000m : 95%rated armature current
h
$ 3000m : 90%rated armature current
h
$ 4000m : 85%rated armature current
Degree of pollution
VDE 0110, part 2, degree of pollution 2
Controllers must not be exposed to a corrosive or explosive
atmo-sphere.
Noise emission
Requirements to EN 50081-2, IEC 22G
Limit-value class A (EN 55011; industrial premises) with RFI filter
Noise immunity
Limit values maintained with RFI filter.
Requirements to EN 50082-2, IEC 22G
Requirements
Standard
Severity
ESD
EN 61000-4-2
3, i.e. 8kV air discharge
6 kV contact discharge
RF interference
IEC 1000-4-3
3, i.e. 10 V/m
(enclosure)
Burst
EN 61000-4-4
3/4, i.e. 2kV / 5kHz
Surge
EN 61000-4-5
3, i.e. 1.2 / 50
ms
1kV phase - phase
2kV phase - PE