Configuration – Lenze EDS4900U-REG User Manual
Page 111

Configuration
7-20
48XX/49XXSHB0399
Code
Name
Possible settings
Lenze
Selection
Info
C025
¤ Input
selection:
Input
adjustment
2
-1-
Terminals X1/1, X1/2
-2-
Terminals X1/3, X1/4
-3-
Terminal X1/6
-4-
Terminal X1/8
-5-
Armature voltage feedback
-10-
Digital frequency input X5
-11-
Digital frequency input X9
-12-
Resolver X7
-13-
Encoder output X8
Select the input which is to be adjusted
with C026, C027, C028 or C029 under
C025.
C026
¤ Encoder
constant
for C025
0mV
C007 = -5-, -6-, -9-, -20-:
Offset correction of the analog inputs
-9999 mV
{1 mV}
+ 9999 mV
The encoder constants are not overwritten
when loading the factory setting.
0V
C025 = -5-:
Offset correction of the armature voltage feedback
-100V
{1V}
+ 100V
1
C025 = -10-, -11-:
Encoder constant of the digital frequency inputs
-0-
8192 increments / revolution
-1-
4096 increments / revolution
-2-
2048 increments / revolution
-3-
1024 increments / revolution
-4-
512 increments / revolution
-5-
256 increments / revolution
3
C025 = -13-:
Encoder constant of the encoder output with resolver
feedback
-1-
256 increments / revolution
-2-
512 increments / revolution
-3-
1024 increments / revolution
-4-
2048 increments / revolution
C027
Gain factor
for C025
1.000
C007 = -5-, -6-, -9-, -20-:
Gain factor of the analog inputs
-2.500
{0.001}
+ 2.500
1.000
With C005 = -11-, -41-:
Gain factor of the tacho input X1/3, X1/4
0.010
{0.001}
+ 9.999
1.010
C025 = -5-:
Gain factor fo the armature voltage feedback
0.100
{0.001}
+ 9.999
0.1000 C025 = -10-, -11-:
Gain factor of the digital frequency input
-3.2767 {0.0001}+ 3.2767
If an analog signal source (C145/C146) is
assigned, the parameter will be displayed
only.
1.000
C025 = -12-:
Gain factor of the resolvers
-32.767 {0.001} + 32.767
C028
Divisor for
C025
0.1000
C025 = -10-, -11-:
Divisor for the digital frequency inputs
0.0001
{0.0001}
3.2767