Configuration – Lenze EDS4900U-REG User Manual
Page 211

Configuration
7-120
48XX/49XXSHB0399
Code
Possible settings
Name
Code
Info
Selection
Lenze
Name
[C005*] Configuration
11
Speed control with additional setpoint
-10-
Armature voltage control
n
set
: analog at X1/8
n
add
: analog at X1/6
M
limit
: analog at X1/1, 1/2.
-11-
Act. value encoder: tacho at X1/3,X1/4
n
set
: analog at X1/8
n
add
: analog at X1/6
M
limit
: analog at X1/1, X1/2
-12-
Act. value encoder: resolver at X7
n
set
: analog at X1/8
n
add
: analog at X1/6
M
limit
: analog at X1/1, X1/2
-13-
Act. value encoder: increment. encoder at X9
n
set
: analog at X1/8
n
add
: analog at X1/6
M
limit
: analog at X1/1, X1/2
If C005 = -10- or -40-, field control
override is not possible.
A change of the configuration changes the
control structure and the terminal
assignment and activates important
monitoring functions.
Change monitoring functions:
C119 / C120
Change terminal signals: C145 / C146.
Torque control with speed limitation and addi-
tional setpoint
-40-
Armature voltage control
n
set
: analog at X1/8
n
add
: analog at X1/6
M
set
: analog at X1/1, 1/2.
-41-
Act. value encoder: tacho at X1/3, X1/4
n
set
: analog at X1/8
n
add
: analog at X1/6
M
set
: analog at X1/1, 1/2.
-42-
Act. value encoder: resolver at X7
n
set
: analog at X1/8
n
add
: analog at X1/6
M
set
: analog at X1/1, X1/2
-43-
Act. value encoder: increment. encoder at X9
n
set
: analog at X1/8
n
add
: analog at X1/6
M
set
: analog at X1/1, X1/2
Dig. freq. of master with additional setpoint
-52-
Act. value encoder: resolver at X7
n
set
: analog at X1/8
n
add
: analog at X1/6
M
limit
: analog at X1/1, X1/2
-53-
Act. value encoder: increment. encoder at X5
n
set
: analog at X1/8
n
add
: analog at X1/6
M
limit
: analog at X1/1, X1/2
Digital frequency bus
-62-
Act. value encoder: resolver at X7
n
set
: digital at X9
M
limit
: analog at X1/1, X1/2
-63-
Act. value encoder: increment. encoder at X5
n
set
: digital at X9
M
limit
: analog at X1/1, X1/2
Digital frequency cascade
-72-
Acutal value encoder: resolver at X7
n
set
: digital, X5
M
limit
: analog at X1/1, X1/2
C009*
¤ Controller
address
1
1
{1}
99
Bus participant number for operation via
interface: Parameter 10 reserved for
broadcasting to groups of participants.
Can only be changed with C001 = -0-
and -1-.