Configuration – Lenze EDS4900U-REG User Manual
Page 117

Configuration
7-26
48XX/49XXSHB0399
Code
Name
Possible settings
Lenze
Selection
Info
C116*
¤ Input
selection:
Freely
assignable
digital
output
1
-1-
FDO 1
-2-
FDO 2
...
-12-
FDO 12
-13-
Relay output X3/K11, X3/K14
The digital outputs FDO1..FDO12 and the
relay output X3/K11, X3/K14 are freelay
assignable with the functions under C117.
Multiple assignment is possible.
The outputs FDO1...FDO5 are assigned to
the terminals X3/A1...X3/A5.
FDO6...FDO12 can only be accessed via
LECOM.
Assignment of functions:
1.Select output under C116.
2.Assign function under C117.
Only for FDO1...FDO5, relay output:
3.Determine polarity under C118.
4.Determine signal delay under C128.
[C117*] Function
for C116
-0-
No function
-1-
n
act
n
x
C017 (FDO1)
-2-
Controller enabled (FDO10)
-3-
n-controller output = M
max
(FDO2)
-4-
Ready for operation (RDY) (FDO11)
-5-
Pulse inhibit (IMP) (FDO12)
-6-
TRIP (relay)
-7-
Warning (FDO6)
-8-
Message (FDO7)
-9-
Ramp function generator Input = Output
(FDO3)
-10-
n
act
= n
set
(FDO5)
-11-
n
act
= 0 (FDO4)
-12-
I
A
= 0 (FDO8)
-13-
I
A
& n
act
= 0 (FDO9)
-14-
C046 or C049 > n
x
(Threshold C243)
-15-
|I
A
| > I
x
(Threshold C244)
-16-
I
F
> I
x
(Threshold C245)
-17-
|n
act
| > n
x
(Threshold C242)
-18-
Brake control
-19-
Comparator 1
-20-
Comparator 2
[C118]
Polarity for
C116
-0-
Output is HIGH active (FDO2, 3, 5)
-1-
Output is LOW active (FDO1, 4, relay)
C128*
Delay for
C116
0.000 s 0.000 s
{0.001 s}
240.000 s
Signal delay times for FDO 1...5 and relay
output.