Configuration – Lenze EDS4900U-REG User Manual
Page 215

Configuration
7-124
48XX/49XXSHB0399
Code
Possible settings
Name
Code
Info
Selection
Lenze
Name
C043*
¤ TRIP reset
-0-
Read: no fault
Write: reset fault
-1-
Read: fault
Only selectable via the interfaces.
C045
¤ JOG enable
0
-0-
Main setpoint (C046) active
-1-
Setpoint JOG1 active
...
-15-
Setpoint JOG15 active
Display only with terminal control.
C046
n
set
speed
-100.0 % n
max
{0.1 %}
+ 100.0 % n
max
Display only with terminal control. If the
terminal control is deactivated, the actual
terminal value will be accepted for
operation.
C047
Torque limit
-100.0 % M
max
{0.1 %}
+ 100.0 % M
max
Display only with terminal control. If the
terminal control is deactivated, the actual
terminal value will be accepted for opera-
tion. Armature setting range: 100 % M
max
correspond to 100 % I
max
(C022, C023)
C049
Additional
setpoint
-100.0 % n
max
{0.1 %}
+ 100.0 % n
max
Display: additional setpoint from terminal
C050
n
set
at controller
-180.0 % n
max
{0.1 %}
+ 180.0 % n
max
Display: speed setpoint at the input of the
speed controller
C051
n
act
speed
-5000 rpm
{1 rpm}
+ 5000 rpm
Display: actual speed
C052*
Motor voltage
0 V
{1 V}
600 V
Display: motor voltage V
A
C054
Motor current
0.0 A
{0.1 A}
100 A
100 A
{1 A}
2000 A
Display: motor current
C056
Torque setpoint
-100.0 % M
max
{0.1 %}
+ 100.0 % M
max
Display: Torque setpoint
Armature setting range: 100% M
max
correspond to 100% I
max
(C022, C023)
C060*
Rotor position
0...2047
Display of the absolute angle position of
the rotor, standardized to 2048 incr./rev.
With incremental encoder feedback,
display only after zero track pulse
occured.
C061*
I
¼t load
0,0 %
{0.1 %}
105,0%
Display: ”I
¼t load”
Starting value when switching on the
mains is always 100 % !
C063
I
set
at controller
-100.0 % I
max
{0.1 %}
+ 100.0% I
max
Display: current setpoint at current
controller input