Configuration – Lenze EDS4900U-REG User Manual
Page 219

Configuration
7-128
48XX/49XXSHB0399
Code
Possible settings
Name
Code
Info
Selection
Lenze
Name
C088
Rated motor
current
0 A
{0.1A}
100 A
100 A
{1A}
3600 A
Rated current depends on the controller:
0..87A
(4902)
0..135A (4903)
0..270A (4904)
0..450A (4905)
0..720A (4906)
0..900A (4907)
0..1200A (4X08)
0..1800A (4X09)
0..2520A (4X11)
0..3600A (4X12)
0..4050A (4X13)
See motor nameplate
C090
¤ Rated motor
voltage
420 V
150 V
{1 V}
650 V
See motor nameplate
Observe max. permissible output voltage
of the controller!
C093*
¤ Controller
identification
49XX
Display: controller type
C094*
User password
0
0
{1}
999
0 = No password protection (see also
C000)
C098
Language
0
-0-
German
-1-
English
-2-
French
C099*
Software
version
49 6.X
Display: Series and software version
C100*
¤ Input selection:
Additional
acceleration and
deceleration
times for main
setpoint
-1-
Acceleration time T
ir1
/deceleration time T
if1
-2-
Acceleration time T
ir2
/deceleration time T
if2
...
-15-
Acceleration time T
ir15
/deceleration time T
if15
Extends T
ir
(C012) and T
if
(C013) by max.
15 value pairs. Can be changed under
C130:
1.Select additional times under C100.
2.Set under C101 (T
ir
) or C103 (T
if
).
C101*
Acceleration
time for C100
0.00s
0 s
{0.01 s}
1 s
1 s
{0.1s}
10s
10 s
{1 s}
100 s
100 s
{10 s}
990 s
Time refers to speed change 0...n
max
C103*
Deceleration
time for C100
0.00s
0 s
{0.01 s}
1 s
1 s
{0.1s}
10s
10 s
{1 s}
100 s
100 s
{10 s}
990 s
Time refers to speed change 0...n
max
C105
Deceleration
time for quick
stop
0.00s
0 s
{0.01 s}
1 s
1 s
{0.1s}
10s
10 s
{1 s}
100 s
100 s
{10 s}
990 s
Time refers to speed change 0...n
max
C108*
Gain for C110
1.00
-10.000 {0.001}
+ 10.000
Gain for X4/62, X4/63, X8
C109*
Offset for C110
0mV
-10000mV
{1mV}
+ 10000mV
Offset for X4/62, X4/63
Loading of the factory settings does not
overwrite C109.
This code is only effective if the digital
frequency output is selected under C110.
C110*
¤ Input selection:
Monitor output
1
-1-
Analog output X4/62 (monitor 1)
-2-
Analog output X4/63 (monitor 2)
-3-
Digital frequency output X8
The monitor outputs are freely assignable
with the signals under C111:
1.Select monitor output under C110.
2.Assign signals under C111.
3.If necessary, adjust under C108 and
C109.