Configuration – Lenze EDS4900U-REG User Manual
Page 220

Configuration
7-129
48XX/49XXSHB0399
Code
Possible settings
Name
Code
Info
Selection
Lenze
Name
[C111*] Signal for C110
-0-
No signal
-1-
Main setpoint (C046), reference: n
max
-2-
Input ramp function generator, reference:
n
max
-3-
Output ramp function generator, reference:
n
max
-4-
Additional setpoint (C049), reference: n
max
-5-
n
set
at n-controller input (C050), reference:
n
max
Armature setting range: 100 % M
max
correspond to 100 % I
max
(C022, C023)
The actual armature current I
act
(C054) is
standardized, according to the controller:
I
act
X4/62,
X8
Type
X4/63
16A
4.4V
110kHz
4902
25A
4.7V
118kHz
4903
55A
4.8V
120kHz
4904
-6-
n
act
(C051), reference: n
max
(X4/63)
-8-
n
act
(C382), reference: n
max
(X8)
-20-
n-controller output, reference: M
max
-21-
M
set
(C047), reference: M
max
-22-
I
set
(C063), reference: I
max
(C022, C023),
(X4/62)
55A
4.8V
120kHz
4904
110A
4.9V
122kHz
4905
200A
6.4V
159kHz
4906
250A
4.4V
110kHz
4907
330A
5.2V
129kHz
4X08
500A
5.8V
144kHz
4X09
700A
5.8V
144kHz
4X11
-23-
I
act
(C054), reference: (see ’Info’)
-25-
M
set
(C056), reference: M
max
-28-
I
¼t load, reference: 100%
-29-
I
2
¼t load, reference: 100%
-30-
V
A
(C052), reference: 1000 V
700A
5.8V
144kHz
4X11
1000A 5.8V
146kHz
4X12
1200A 7.0V
175kHz
4X13
With C111 = -5- the selection depends on
the configuration set under C005.
If C005
6X
72 th
i
l C111
-35-
Mains frequency, reference: 30Hz = 0V,
70Hz = 10V
-40-
Fiel current setpoint, reference: max.
controller field current I
Fmax
-41-
Actual field current, reference: I
Fmax
-60-
Output motor potentiometer, reference:
100%
If C005 = -6X-, -72- the signal C111 =
-5- outputs the corresponding input pulse
current.
-61-
Output process controller, reference: 100%
-62-
Output arithmetic block 2, reference: 100%
-63-
Digital frequency input X5, reference: 100%
-64-
Digital frequency input X9, reference: 100%
-65-
Resolver, reference: 100%
-66-
Digital / analog conversion 1 (C272),
reference: 100%
-67-
Digital / analog conversion 2 (C273),
reference: 100%
-68-
Motor power, reference: 5 V = P
rated
-69-
Motor torque, reference: 5 V = M
rated
-70-
Output dead band element, reference: 100%
-71-
Output DT1 element, reference: 100%
-72-
Output absolute value generator, reference:
100%
-73-
Output limiting element 1, reference: 100%
-74-
Output PT1 element, reference: 100%
-75-
Output arith.-block 3, reference: 100%
-76-
Output add.-block 1, reference: 100%
-77-
Output add.-block 2, reference: 100%
-78-
Output limiting element 2, reference: 100%
Show/Hide Bookmarks