2 mains switch-off logic, Mains switch-off logic, Selection aid – Lenze EDS4900U-REG User Manual
Page 317: 2 mains switch-off logic stop, Contactor or relay circuit

Selection aid
15-25
48XX/49XXSHB0399
Contactor or relay circuit
4900Str110
2 0 2 1
2 8
3 9 4 0
5 9
9 0 F E
X 2
X 3
X 4
4 9 0 0
2 2
A 4
K 3
S 1
S 2
K 2
K 2
K 2 . 1
K 1
K 2 . 1
K 4
K 3
K 1
t d
L 1 1
L 1 0
L 2 0
K 4
K 5
K 4
S 4
K 2
S 3
1 2
K 5
K 1
R F R
R
L
Q S P
n a c t = 0
t d > t B r .
D i r e c t c o n n e c t i o n t o c o n t r o l c a b l e " O N "
" E m e r g e n c y o f f " c a b l e
FIG 15-12
Connection of the signal electronics for tipping operation via momentary-contact pushbutton S4
K1
Controller mains contactor
K2.1
Safety relay for mains isolation if no standstill message is indicated
K4, K5
Relay with gold-plated contacts
S1
Drive off
S2
Drive on
S3
1: Tipping / 2: Automatic
S4
Inching
L10
Direct cable from the control cable ’on’
L11
’Emergency-Off cable
15.9.2
Mains switch-off logic
Stop!
The controllers 48XX/49XX must only be separated from the mains when they are
inhibited or the motor is in standstill.
This also applies to the emergency-off function.
The function |n
act
| < C019 can be used for the mains switch-off logic.
The digital output terminal A4 is for automatic mains switch-off. The terminals sets
”low”, if the actual speed value is lower than the value set under C019. The
threshold can be set under C019 from 0 to 5000 rpm. For this application, the
setting must not exceed 2% n
rated
.