Configuration – Lenze EDS4900U-REG User Manual
Page 127

Configuration
7-36
48XX/49XXSHB0399
Adaptation of the signal at the digital frequency output X8
If another signal than stated in the basic configuration (C005) is assigned, the
output frequency is adjusted via code C108.
Configurat
ion
Basic assignment
Adaptation of the output
frequency with ...
Notes
C005
C026 if
C025 = -13-
C030
C108
-10-, -40-
n
act
from C382
-
-
active
-11-, -41-
n
act
from C382
-
-
active
-12-, -42-
n
act
from C051
Selection
possible
-
-
The rotor zero position, which depends on
the resolver, is output on the zero track.
-13-, -43-
n
act
from C051
-
-
-
The encoder constant is only by the
incremental encoder used (hardware). A
zero track is only output if it is provided by
the incremental encoder.
-5x-
n
set
from C050
-
Selection
possible
-
The output signal is normalized to the
number of pulses of the incremental
encoder. A zero track will not be output.
-6x-
n
set
from C050
-
-
-
At the output X8 the signal from X9 is
directly output (electrically buffered). A zero
track is only output, if it is connected to
input X9.
-72-
n
set
from C050
-
Selection
possible
-
The output signal is normalized to the
number of pulses of the incremental
encoder. The corresponding encoder
constant can only be set under C030. The
gain can be set via C027 and C028 of the
input X5 (C025 = -10-). A zero track will
not be output.
The sign ”-” means that a change does not influence the output frequency.
Show/Hide Bookmarks