Installation, Analog inputs – Lenze EDS4900U-REG User Manual
Page 53

Installation
4-15
48XX/49XXSHB0399
Analog inputs
Terminal
Switch position
Use
Level
Resolution
1, 2
2
S3
ON
OFF
Setpoint 2
with ground reference (factory
setting)
-10V...+ 10V
12 bit + sign
2
S3
ON
OFF
Setpoint 2
differential input
-10V...+ 10V
12 bit + sign
3, 4
1 2 3 4
S4
ON
OFF
Actual value
-10V...+ 10V
12 bit + sign
1
2 3 4
S4
ON
OFF
Actual value
-30V...+ 30V
12 bit + sign
1
2
3 4
S4
ON
OFF
Actual value
-60V...+ 60V
12 bit + sign
1 2
3 4
S4
ON
OFF
Actual value (factory setting)
-73V...+ 73V
12 bit + sign
1 2
3
4
S4
ON
OFF
Actual value
-90V...+ 90V
12 bit + sign
1
2
3
4
S4
ON
OFF
Actual value
-99V...+ 99V
12 bit + sign
1 2 3
4
S4
ON
OFF
Actual value
-120V...+ 120V
12 bit + sign
1
2
3
4
S4
ON
OFF
Actual value
-180V...+ 180V
12 bit + sign
5
S4
ON
OFF
Actual value
with ground reference
12 bit + sign
5
S4
ON
OFF
Actual value
differential input
1)
12 bit + sign
6
Setpoint 3 with ground reference
-10V...+ 10V
12 bit + sign
7
Internal ground, GND
8
1
S3
ON
OFF
Setpoint 1,
Master voltage (factory setting)
-10V...+ 10V
12 bit + sign
1
S3
ON
OFF
Setpoint 1,
Master current
-20mA...+ 20mA
-20 mA...-4 mA
+ 4 mA...+ 20 mA
9
Voltage supply for
+ 10V/7mA
10
Setpoint selection via potentiometer -10V/7mA
Show/Hide Bookmarks